日本財団 図書館



  In general, transformers and condensers should be carried in leakproof metal
  packagings which are capable of holding, in addition to the transformers and
  condensers, at least 1.25 times the volume of the liquid present in them. There should
  be sufficient inert absorbent material in the packagings to absorb at least 1.1 times the
  volume of liquid which is contained in the transformers or condensers. Tue
  transformers or condensers should not be overstowed.

  Notwithstanding the above, Iiquids and solids not packaged in accordance with table 1
  or 2 of the introduction to class 6.1 and unpackaged transformers and condensers
  should be stowed in cargo transport units fitted with a leakproof metal tray to a height
  of 800mm, containing sufficient inert absorbent material to absorb at least 1.1 times
  the volume of any free liquid.

  Adequate provision should be made to seal the transformers and condensers to ensure
  that leakage during transport is minimized."

.2 Under packing include the following reference:
  "For IBCs see section 26 of the General Introduction."

前ページ    目次へ    次ページ

 






日本財団図書館は、日本財団が運営しています。

  • 日本財団 THE NIPPON FOUNDATION