日本財団 図書館


(9) 熱収縮チューブ加熱試験結果グラフ、表、写真
 
表7.5.2.(5)(9)
NO. 介在物中 外装下 チューブ下 周囲温度
1 35.2 35.2 35.5 35.5
2 35.3 35.4 35.7 35.6
3 35.3 35.3 37.1 35.6
4 35.2 35.4 92.7 35.5
5 35.2 38.7 134.5 35.4
6 35.4 46.5 144.3 35.5
7 35.3 56.0 141.4 35.5
8 35.5 63.0 134.8 35.5
9 35.6 66.4 128.1 35.5
10 35.9 68.1 121.8 35.5
11 36.3 68.9 116.5 35.5
12 37.0 69.5 112.0 35.5
13 37.4 69.7 107.7 35.5
14 38.0 69.7 104.0 35.5
15 38.6 69.7 100.2 35.5
16 39.2 69.5 96.4 35.5
17 39.7 69.2 93.5 35.5
18 40.3 68.7 91.2 35.5
19 40.7 68.2 89.1 35.5
20 41.3 67.7 86.9 35.5
21 41.7 67.2 85.0 35.5
22 42.3 66.6 83.3 35.5
23 42.8 66.0 81.8 35.5
24 43.0 65.3 80.3 35.5
25 43.4 64.9 78.7 35.5
26 43.8 64.5 76.9 35.5
27 44.2 63.9 75.5 35.5
28 44.5 63.2 74.1 35.5
29 44.7 62.5 72.9 35.5
30 45.1 62.0 71.7 35.5
31 45.3 61.5 70.6 35.5
32 45.6 61.0 69.4 35.5
33 45.7 60.5 68.2 35.4
34 45.9 60.0 67.2 35.5
35 46.2 59.7 66.6 35.5
36 46.4 59.2 65.8 35.5
37 46.5 58.7 65.1 35.5
38 46.6 58.2 64.2 35.5
39 46.7 57.8 63.5 35.5
40 46.7 57.4 62.9 35.5
41 46.7 57.0 62.2 35.5
42 46.9 56.7 61.7 35.5
43 46.9 56.3 61.2 35.5
44 46.9 56.0 60.5 35.5
45 46.9 55.6 59.7 35.5
46 46.9 55.3 59.1 35.5
47 46.9 55.0 58.1 35.5
48 47.0 54.7 57.2 35.5
49 47.0 54.3 56.5 35.5
50 47.1 54.1 56.0 35.5
51 47.1 53.7 55.5 35.5
52 47.1 53.4 55.0 35.6
53 47.1 53.1 54.5 35.5
54 47.0 52.8 54.0 35.5
55 46.9 52.5 53.3 35.5
56 46.9 52.2 52.8 35.5
57 46.8 51.9 52.5 35.5
58 46.9 51.7 52.2 35.5
59 46.8 51.3 51.8 35.5
60 46.8 51.1 51.5 35.5
61 46.7 50.8 51.2 35.5
 
NO.9
電線種類 TPYCY-10
電線パイプ SGP-25
熱収縮チューブ NOR-A 35-8-2.5
温度表示間隔 5秒
 
図7.5.2.(5)(9)
 
写真7.5.2.(5)(9)
 
目視検査の結果
 熱収縮チューブは防食シースに融着しており剥離することが出来なく、防水性は良いと思われる。
 電線内部はがい装、ビニールシース、介在物、電線絶縁体とも異常は見られない。
 
(10)熱収縮チューブ加熱試験結果グラフ、表、写真
 
表7.5.2.(5)(10)
NO. 介在物中 外装下 チューブ下 周囲温度
1 35.3 35.3 35.4 35.1
2 35.4 35.4 38.5 35.3
3 35.5 35.4 36.4 35.3
4 35.5 35.4 37.8 35.3
5 35.5 35.5 43.0 35.2
6 35.5 36.3 64.2 35.2
7 35.6 38.5 96.4 35.2
8 35.6 43.2 118.1 35.3
9 35.5 49.4 131.7 35.2
10 35.6 56.2 144.1 35.3
11 35.8 62.7 151.7 35.3
12 36.2 68.5 155.0 35.4
13 36.6 73.2 155.5 35.2
14 37.6 77.1 154.6 35.3
15 38.6 79.9 152.5 35.2
16 39.9 82.4 150.2 35.3
17 41.5 84.0 147.5 35.3
18 43.1 85.4 144.3 35.2
19 45.0 86.4 141.5 35.3
20 46.8 87.1 138.4 35.3
21 48.7 87.6 135.6 35.3
22 50.3 87.9 132.5 35.2
23 52.0 88.1 129.5 35.3
24 53.6 88.0 126.8 35.3
25 55.0 87.9 124.3 35.3
26 56.4 87.8 122.0 35.2
27 57.6 87.6 119.9 35.2
28 58.7 87.3 117.9 35.2
29 59.7 87.0 116.1 35.2
30 60.6 86.5 114.4 35.2
31 61.5 86.1 112.7 35.3
32 62.0 85.7 111.1 35.2
33 62.8 85.5 109.6 35.3
34 63.4 85.0 108.1 35.3
35 63.8 84.5 106.5 35.4
36 64.1 84.0 105.2 35.3
37 64.5 83.6 103.9 35.3
38 64.8 83.1 102.6 35.3
39 64.9 82.7 101.1 35.2
40 65.1 82.1 100.0 35.2
41 65.3 81.7 98.9 35.3
42 65.3 81.2 97.7 35.4
43 65.3 80.7 96.5 35.3
44 65.3 80.2 95.3 35.2
45 65.3 79.8 94.3 35.3
46 65.4 79.3 93.3 35.4
47 65.3 78.8 92.4 35.3
48 65.2 78.3 91.4 35.2
49 65.2 77.9 90.7 35.3
50 65.1 77.5 89.7 35.3
51 65.0 77.0 89.0 35.4
52 65.0 76.7 88.4 35.5
53 65.0 76.3 87.7 35.5
54 64.8 75.9 86.9 35.5
55 64.5 75.4 86.3 35.5
56 64.4 75.0 85.6 35.5
57 64.2 74.5 84.9 35.4
58 64.1 74.1 84.2 35.5
59 63.9 73.8 83.4 35.5
60 63.7 73.3 82.7 35.5
61 63.6 72.8 82.2 35.5
62 63.4 72.3 81.6 35.5
63 63.1 71.8 81.0 35.5
 
NO.10
電線種類 TPYCY-10
電線パイプ SGP-40
熱収縮チューブ NOR-A 65-15-3
温度表示間隔 5秒
 
図7.5.2.(5)(10)
 
写真7.5.2.(5)(10)
 
目視検査の結果
 熱収縮チューブは防食シースに融着しており剥離することが出来なく、防水性は良いと思われる。
 電線内部はがい装、ビニールシース、介在物、電線絶縁体とも異常は見られない。


前ページ 目次へ 次ページ





日本財団図書館は、日本財団が運営しています。

  • 日本財団 THE NIPPON FOUNDATION