2 Proctor/Fagerberg test
Poland and Japan carried out Proctor/Fagerberg tests in accordance with D.1.3 of the BC Code. The results of the tests carried out by Japan are shown in Figure 3.1 to 3.5. In each figure, the ordinate and the abscissa denote void ratio and net moisture content by volume, respectively. The black circles indicate the measured data. The straight line corresponds to degree of saturation 70%.
Fig. 3.1 Compaction Curve for Iron Conc.
Fig. 3.2 Compaction Curve for Copper Conc.
Fig. 3.3 Compaction Curve for Zinc Conc.
Fig. 3.4 Compaction Curve for Nickel Slag