8.1.2 Non tested laminates
Where the mechanical properties have not been verified by tests the respective properties shall be determined according to one of the following options:
8.1.3 Determination of glass content
Option 1:
The fibre mass content for each individual layer may be determined from Table 9 and using the law of mixture.
Option 2:
The glass content may be determined by direct measurement of the laminate without the gel coat and/or a burn-out test.
A minimum of five samples shall be used.
8.1.4 Calculation of mechanical properties