5.4 Watertight bulkheads and integral tank bulkheads, design pressure

 

5.4.1 Watertight bulkheads

The design pressure Pbkd on watertight bulkheads is to be taken as:

 

Pbkd = 7,2・hb kN/m2 (16)

 

where hb load head in metres, measured vertically as follows:

 

Plating: The distance from a point one third of the height of the plate above its lower edge to the bulkhead deck at side.

Stiffeners: The distance from mid point of stiffener span to the bulkhead deck at side.

 

025-1.gif

Figure 10 Watertight Bulkheads

 

5.4.2 Integral tank bulkheads

 

025-2.gif

 

 

 