6 Conformance requirements(ユニバーサル造船)
ここではN1144文書のConformance requirementsについてN1074のConformance requirementsとの比較を行う。
適合性クラスのN1074とN1144文書の比較結果を以下に示す。
表1. N1074とN1144のConformance requirementsのClass一覧
| N1074 |
N1144 |
| Class 1 piping system functional in formation |
class 1 piping system functional information; |
| Class 2 equipment and component spatial information |
class 2 equipment and component spatial information; |
| Class 3 plant layout and piping design information |
class 3 plant layout and piping design information; |
| Class 4 piping fabrication and installation information |
class 4 piping fabrication and installation information; |
| Class 5 piping inspection information |
class 5 piping inspection information; |
| Class 6 HVAC system functional information |
class 6 HVAC system functional information; |
| Class 7 HVAC spatial information |
class 7 HVAC spatial information; |
| Class 8 cableway spatial information |
class 8 cableway spatial information; |
| Class 9 piping and HVAC analysis information |
class 9 piping and HVAC analysis information |
|
上記の表でClass数および名称に変更点がないことを確認した。
各適合性クラスが参照するAAMとの関係は前年度報告書と差がないためここでは省略する。
適合性クラスの詳細についてもN1074とN1144で差がないことを確認しているためここでは省略する。
以下にUoFと適合性クラスの関係を示した表をN1074文書から添付する。
表2. N1074文書のUoFと適合性クラスの対応表
| Table 2 − Conformance classes |
| Units of functionality |
Conformance classes |
1
PSFN |
2
EPSP |
3
PLSP |
4
PFB |
5
PIN |
6
HSFN |
7
HSP |
8
CSP |
9
PHAN |
| Cableway_component_charaterzation |
− |
− |
X |
− |
− |
− |
|
X |
− |
| Connection |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Connector |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| HVAC_component_characterization |
− |
− |
X |
− |
− |
X |
X |
− |
X |
| HVAC_system_functional_characterzation |
− |
− |
X |
− |
− |
X |
X |
− |
X |
| Piping_inspection |
− |
− |
− |
− |
X |
− |
− |
− |
− |
| Piping_component_characterization |
X |
X |
X |
X |
X |
− |
− |
− |
X |
| Piping_system_functional_characterzation |
X |
X |
X |
− |
− |
− |
− |
− |
X |
| Piping_item_characterization |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Shape |
X |
X |
X |
X |
X |
X |
X |
X |
X |
Shape_representation(Note1)
(optionA, or B, or C) |
|
A,B,C |
A,B,C |
A,B,C |
A,B,C |
|
A,B,C |
A,B,C |
|
| Change information(optionR) |
R |
R |
R |
R |
R |
R |
R |
R |
R |
| Plant_characterization(optionP) |
P |
P |
X |
P |
P |
P |
P |
P |
P |
| Site_characterization(optionS) |
S |
S |
S |
S |
S |
S |
S |
S |
S |
|
以下に UoFと適合性クラスの関係を示した表をN1144文書から添付する。
表6. Nl144文書の UoFと適合性クラスの対応表
| Units of functionality |
Conformance classes |
1
PSFN |
2
EPSP |
3
PLSP |
4
PFB |
5
PIN |
6
HSFN |
7
HSP |
8
CSP |
9
PHAN |
| Cableway_component_charaterzation |
− |
− |
X |
− |
− |
− |
− |
X |
− |
| Connection |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Connector |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| HVAC_component_characterization |
− |
− |
X |
− |
− |
X |
X |
− |
X |
| HVAC_system_functional_characterzation |
− |
− |
X |
− |
− |
X |
X |
− |
X |
| Piping_inspection |
− |
− |
− |
− |
X |
− |
− |
− |
− |
| Piping_component_characterization |
X |
X |
X |
X |
X |
− |
− |
− |
X |
| Piping_system_functional_characterzation |
X |
X |
X |
− |
− |
− |
− |
− |
X |
| Piping_item_characterization |
X |
X |
X |
X |
X |
X |
X |
X |
X |
| Shape |
X |
X |
X |
X |
X |
X |
X |
X |
X |
Shape_representation(Note 1)
(Options A, or B, or C) |
|
A,B,C |
A,B,C |
A,B,C |
A,B,C |
|
A,B,C |
A,B,C |
|
| Plant Usage Option(OptionP,S) |
P.S |
P.S |
P.S |
P.S |
P.S |
P.S |
P.S |
P.S |
P.S |
| Hull applicability(OptionH) |
H |
H |
H |
H |
H |
H |
H |
H |
H |
| Associative schematics(OptionM) |
M |
M |
M |
− |
− |
M |
M |
M |
M |
| Change information(OptionR) |
R |
R |
R |
R |
R |
R |
R |
R |
R |
| Site_characterization(OptionT) |
T |
T |
T |
T |
T |
T |
T |
T |
|
|
上記の表中で用いる記号について以下に示す。
| 記号 |
説明 |
| X |
XはARMにおけるすべてのEntityに含まれることを示す |
| A |
Aは形状を境界表現モデルを用いて表すEntityであることを示す |
| B |
Bは形状を単純なCSGモデルを用いて表すEntityであることを示す |
| C |
Cは形状をハイブリッドCSGを用いて表すEntityであることを示す |
| R |
Rは変更情報UoFのためのEntityであるを示す |
| P |
Pはプラント特性UoFのためのEntityであることを示す |
| S |
Sは用地特性UoFのためのEntityである示す |
| PSFN |
Piping system functional information |
| EPSP |
Equipment and piping spatial information |
| PLSP |
Plant spatial information |
| PFB |
Piping fabrication and installation information |
| PIN |
Piping inspection information |
| HSFN |
HVAC system functional information |
| HSP |
HVAC spatial information |
| CSP |
Cableway spatial information |
| PHAN |
Piping and HVAC analysis information |
| H,M,R |
UoF用のARMがもつEntityを含むことを示す |
|
以上からHull_ApplicabilityおよびAssociative_schematicsにオプションで対応していることを確認した。
適合性クラスとAIMエンティティの関係については原文を参照のこと。
|