(96) Re: HOLD CLEANLINESS: The last sentence should be read as follows:

"Hold should be lime washed or coated with paint which has equivalent function to prevent corrosion of structure due to salt on tank tops, hoppers, side shells and bulkhead plates which cargo contact with."

Reason: Means for protection of cargo holds from corrosion other than lime coating are utilized and there is no reason to prohibit such means.

 

My former comment No.71 is substituted by this comment.

 

Re: UREA

(97) Re: CLEAN UP: The sentence should be read as follows:

"Pure urea does not corrode steel but in water solution strip some kinds (e.g., rubber chloride) of paintwork. Impure urea with ammonium may corrode steel structure and in water solution strip some kinds of paintwork. Sweep, hose out and dry holds."

Reason: In general, urea carried in bulk contains impurities and the corrosions of structure and paint have been reported.

 

Re: CEMENT

Re: CEMENT CLINKER

(98) Re: CARRIAGE: The sentences should be read as follows:

"Hatches should be sealed, if necessary. Shut all vents and access ways. DO NOT pump bilges in cement hold without special precaution, because pumping of water containing cement may cause malfunction of the pumping system."

Reason: Japanese shipping companies have long experience of the carriage of these cargoes. Sealing of cargo hold is necessary in general but not always.

 

My former comment No.23 is substituted by this comment.

 

(99) Re: CLEAN UP: The following sentences should be added:

"DO NOT pump hold washing water without special precaution, because pumping of water containing cement may cause malfunction of the pumping system."

Reason: To prevent disorder of the ship's bilge pump, different pump is used for discharging hold washing water.

 

Re: ALUMINIUM SILICON POWDER, UNCOATED UN No.1398

Re: FERROSILICON UN No: 1408 with 30% or more but less than 90% silicon

Re: FERROSILICON BC No.022 containing 25% to 30% silicon, or 90% or more silicon

 

(100) Re: Fixed fire extinguishing system in EmS

In the EmS (B2) for these cargoes, "EMERGENCY ACTION IN A FIRE SITIJATION" should be as read follows:

"Batten down and use CO2 if available. Do not use water."

Reason: Editorial. These cargoes constitute low fire risk and installation of a fixed fire-extinguishing system is not required (c.f. MSC/Circ.671 Table 1).

 

Re: SULPHUR (lump and coarse grained) UN No: 1350

(101) Re: Fixed fire extinguishing system in EmS

In accordance with the existing EmS - B9, a fixed fire-extinguishing system should be used in a fire situation. On the other hand, this cargo is regarded as a low fire risk cargo and fixed gas fire-extinguishing system is not required. For this cargo, water should not be used. Therefore, the sentence in the EmS for this cargo should be changed as follows:

"Batten down; use ship's fixed fire-fighting installation, if available.

Exclusion of air may be sufficient to control the fire. Do not use water."

 

Re: LIME (UNSLAKED) BC No: 030

CALCIUM OXIDE

DOLOMITIC QUICKLIME

QUICKLIME

(102) Re: EMERGENCY ACTION IN A FIRE SITUATION

The remark "Do not use water if involved in a fire" under the EmS is better to be positioned in the column for "EMERGENCY ACTION IN A FIRE SITUATION".

 

Re: ALLUMlNUM SILICON POWDER, UNCOATED UN NO: 1398

(103) Re: PRECAUTIONS - Self-contained breathing apparatus

I support the comment by the Netherlands to amend the sentence as follows:

163-1.gif

 

(104) Re: FIRE PROTECTION IN CARGO SPACES - UK comment No.2

I support the original sentence. The EmS should be amended (c.f. my comment No.100).

 

Re: AMMONIUM NITRATE UN MO: 1942

(105) Re: STOWAGE & SEGREGATION

I consider that the sentences in this column in the former draft should not be deleted.

 

Re: BAUXITE

 

 

 