日本財団 図書館


BLG 4/18

ANNEX 13

Page 2

 

The hose should be stencilled or otherwise marked with the date of testing, its specified maximum working pressure and, if used in services other than the ambient temperature services, its maximum and minimum service temperature, as applicable. The specified maximum working pressure should not be less than 10 bar gauge."

 

DRAFT AMENDMENTS TO THE CODE FOR THE CONSTRUCRION AND EQUIPMENT OF SHIPS CARRYING DANGEROUS CHEMICALS IN BULK (BCH CODE)

 

Chapter II

 

Cargo containment

 

2.12 Cargo hoses carried aboard the ship

 

Existing section 2. 12 is replaced by the following:

 

"2.12 Ship's cargo hoses

 

2.12.1 Paragraphs 2.12.2 to 2.12.4 apply to cargo hoses installed on board ships on or after [date of entry into force of amendments] [1 July 2002].

 

2.12.2 Liquid and vapour hoses used for cargo transfer should be compatible with the cargo carried and suitable for the cargo temperature.

 

2.12.3 Hoses subject to tank pressure or the discharge pressure of pumps should be designed for a bursting pressure not less than 5 times the maximum pressure the hose will be subject to during cargo transfer.

 

2.12.4 Each new type of cargo hose, complete with end-fittings, should be prototype-tested at a normal ambient temperature with 200 pressure cycles from zero to at least twice the specified maximum working pressure. After this cycle pressure test has been carried out, the prototype test should demonstrate a bursting pressure of at least 5 times its specified maximum working pressure at the extreme service temperature. Hoses used for prototype testing should not be used for cargo service. Thereafter, before being placed in service, each new length of cargo hose produced should be hydrostatically tested at ambient temperature to a pressure not less than 1.5 times its specified maximum working pressure but not more than two-fifths of its bursting pressure. The hose should be stencilled or otherwise marked with the date of testing, its specified maximum working pressure and, if used in services other than the ambient temperature services, its maximum and minimum service temperature, as applicable. The specified maximum working pressure should not be less than 10 bar gauge."

 

 

 