5.2.2 Operational controls
The INS should be designed and implemented so that the OOW easily operates basic functions from work stations.
5.2.3 Presentation of information
Continuously displayed information should be optimised and should include position, speed, heading and time. Supplementary information should be readily accessible.
6 Design and installation
6.1 General
The INS should meet the relevant requirements of Resolution A.694(17)*.
6.2 Dependability
The INS should be designed to ensure it can operate in a predictable and dependable** manner.
6.3 Failure analysis
A failure analysis*** should be performed and documented for the installed configuration of the INS which includes all parts connected to or integrated into the system, including devices for manual override of automatic functions and their locations on the bridge.
6.4 Installation requirements
The INS should be installed so that it can meet the requirements of the relevant International Standards****.
6.5 Power supply
6.5.1 Power supply requirements
6.5.1.1 Power supply requirements applying to parts of the INS as a result of Other IMO requirements should remain applicable.
* IEC 60945
** IEC 60300 Series
*** IEC 61508
**** IEC 92-101 and IEC 533