In case that the degree of saturation of the sample after drainage SrDR is less than 70%, it is judged that the material is not liable to liquefy.
3.4 Range of application of test result
In case that a material was judged as not liable to liquefy by the LPT, the test result for this material is applicable to materials satisfying all the following conditions:
(i) the material was produced in the same factory, through the same procedure and from the same raw materials including surface active agents:
(ii) the density of the solid material is within the range of 98.5% to 101.5% of the density of the solid material of the cargo having been tested; and
(iii) D10 of the material is not smaller than that of the material having been tested.