? TFT Color LCD Displays and Optical Touch-Screen Control Panels:
・Crisp TFT color LCD Displays incorporating easy-to-operate optical touch screen control panels reduce the unit size and improve its functionalityand reliability.
? Information from screens that can offer display of 8 different modes:
・ Display Table (See Table 1.)
Of particular interest to note is the EVENT DATA display screen that can show the records of up to 240 events, including the occurrence of alarms restoration to normal, motor start/stop events, etc., in order of event occurrence, together with the time that each event occurred.
? Improved Recording Devices:
・ Logging Table (See Table 2. )
Comes standard with an alarm printer and log printer.
? Ability to handle up to 760 input points:
・ This number has been selected as the maximum number of input points that are likely to be required by the automation of the engine room (256 analog input points and 504 digital input points).
? Download function:
・ Allow users to add or change monitoring points.
? Improved Self-diagnostic function:
・ Maintenance procedures are shown on the SYSTEM STATUS display screen to assist ships' crew in carrying out maintenance.
? Improved Optional Functions:
Meter controllers
Lamp controllers
Extension displays
Data communication with other systems

 

 

 