日本財団 図書館


 

MEPC39/6/1
ANNEX
Page52
APPENDIX6
CALIBTATION OF THE ANALYTICAL INSTRUMENTS
1 INTRODUCTION
1.1 Each analyser used for the measurement of an engine's parameters shall be calibrated as necessary in accordance with the requirements of this appendix.
2.2 Except as otherwise specified, all results of measurements, test data or calculations required by this appendix shall be recorded inthe engines's test report in accordance with section 5.10 of this Code.
1.3 Accuracy of analytical instruments
1.3.1 Permissible deviation of instruments shall be traceable to national (international) standards and shall comply with the requirements as set out in tables 1 and 2.

Table 1. Engine related permissible deviations for measurements on a test bed

 

MEPC39/6/1
ANNEX
Page53

056-1.gif

Table 2. Permissible deviations of essential measured parameters for measurements on a test bed

056-2.gif

056-3.gif

1.3.2 Peermissible deviation of instruments for measurements on board a ship for verification purposes
The calibration of all measuring instruments shall be traceable to national (international) standards and shall comply with the requirements as set out in tables 3 and 4.

Table 3. Permissible deviation of instruments for engine related parameters for mesasurements on board a ship

056-4.gif

Table 4. Permissible deviations of instruments for other essential parameters for measurements on board a ship

056-5.gif

 

 

 