日本財団 図書館


Re: CALCINED PYRITES BC No: 003 - GROUP

(142) The GROUP of this cargo is "A and B". The GROUP in Appendix 4 is correct.

 

Re: CARBORUNDUM - PRECAUTIONS

(143) I agree with the deletion of 2nd sentence.

 

Re: CHROMITE ORE - HAZARD

(144) The text for toxicity due dust inhalation should be kept.

 

Re: COAL BC No: 010 - VENTILATION

(145) I consider that the text "Refer to the appendix" should be kept and the text "natural surface ventilation" should be deleted.

 

Re: COAL SLURRY - VENTILATION COKE BREEZE

(146) This cargo is not categorized into GROUP B. Regarding the comment by the UK, prior to discuss on the precautions for the detection of gases, the information on the properties of the cargo should be examined. If there is a hazard due to emission of methane, it should be described in the column for HAZARD. This entry should be discussed at DSC 6, because we have little information at present.

 

Re: COPRA UN No: 1363 - VENTILATION

DIRECT REDUCES IRON BC No: 016 - VENTILATION

(147) The previous text "adequate surface ventilation should be provided" is suitable.

 

Re: DIRECT REDUCES IRON, Briquettes, hot-moulded BC No: 016

(148) I agree with the transfer of the sentences from WEATHER PRECAUTIONS to PRECAUTIONS as proposed by the Coordinator.

(149) Regarding the comment by the UK on hydrogen measurement, prior to discuss on this issue, the information on the properties of the cargo should be examined.

 

Re: DIRECT REDUCES IRON, such as lumps, pellets and cold-moulded briquettes BC No: 015

(150) I agree with the text proposed by the Coordinator for PRECAUTION. "This cargo should not be ventilated" is suitable for VENTILATION.

 

Re: FEROPHOSPHOROUS BC No: 020 - WEATHER PRECAUTIONS

(151) I agree with the comment by the Coordinator.

 

Re: FERROSILICON UN No: 1408 - VENTILATION

FERROSILICON BC No: 022 - VENTILATION

(152) I can not agree with the text proposed by the UK and I am of the opinion that the following text should be kept in this column, because continuous ventilation defined in paragraph 3.5 in the BC Code is not necessary for this cargo:

"The cargo spaces should be provided with an effective power ventilation system. Ventilation fans should normally be run continuously whenever cargoes are on board. Where this is impracticable, they should be operated as weather permits and in any case for a reasonable period prior to discharge."

It should be noted that cargoes for which continuous ventilation is required can not be carried by existing bulk carriers for the carriage of this cargo. On the other hand, Japan has experience of carriage of this cargo by bulk carriers not fitted with special ventilation ducts and no accident due to discontinuity of ventilation is reported. Therefore, I wrote the sentence intentionally to avoid the confusion with continuous ventilation.

 

Re: FEROPHOSPHOROUS BC No: 020 - VENTILATION

(153) I can not agree with the Coordinator's comment by the same reason mentioned above.

 

Re: FERROUS METAL BORINGS, SHAVINGS, TURNINGS OR CUTTINGS UN No: 2793 - VENTILATION

(154) Based on the existing entry for this cargo, I understand that this cargo should not be ventilated during voyage to prevent self-heating and spontaneous ignition and this cargo should be ventilated prior to discharge to prevent an accident due to depletion of oxygen. Therefore, the following text may be appropriate:

"This cargo should not be ventilated during voyage. See also DISCHARGE."

 

Re: FISHMEAL STABILIZED UN No: 2216

 

Re: CHARACTERISTICS

(155) The GROUP of this cargo should be "B or C". The approximate TML should be deleted, because this cargo is not liable to liquefy.

 

Re: VENTILATION

(156) The text "natural surface ventilation" should be deleted.

 

Re: ILMENITE SAND

(157) I would like explain about the conflict of the descriptions for this cargo.

・ In the existing BC Code (1998 Edition), ILMENITE is in Appendix A and ILMENITE SAND is in Appendix C.

・ The BCSN for ILMENITE is "ILMEMTE SAND".

・ For example, the TML of a sample of ILMENITE measured in Japan was 7.7 % (FMP: 8.5 %). Ninety percents of the particles of the sample were 0.15 to 0.5 mm.

 

 

 